Manufacturer: Seagate Model: ST34501W TD# 270262
Interface... UltraSCSI Formatted Capacity... 4,550 MB
Cylinders 6526 Heads 8 Sectors Variable
Landing Zone Cyl + 1 Precomp N/A RWC Cyl N/A
Encoding Method PRML Xfer/Mb 40 MTBF (Hr X 1000) 1000
Form factor 3.5" Novell Y/N Y Height 1"
Power (Typical) 6.74W Power (Max) 11.1W Speed (rpm) 10,000
Avg seek (ms) 8 Cache 512k Mfg. Warranty 5 YRS

NOTE: Can also be operated according to SCSI-1, SCSI-2, and SCSI-3 protocols.
Copyright ⌐ 1996, 1997 Tech Data Corporation


Configuration and Jumper Options

If your system is "SCAM" (SCSI Configured Auto Magically) compliant, the system assigns the drive ID over the interface, so there is no need to be concerned about drive ID. Setting the drive ID jumpers doesn’t hurt anything, but is not necessary.
If your system is not "SCAM" compliant you do need to set the drive ID using the ID jumpers. Optional connections to switching circuits in host equipment are provided on J1 auxillary to set the SCSI ID. (See Below)

Image of Drive showing Jumpers

Image of Drive showing alt Jumpers


Terminating the drive

The ST34501W drives are terminated with permanently mounted IC active terminators. If you install one of these drives and it is not on the end of the SCSI bus, disable the terminators by removing the jumper from pins 15 and 16 of connector J2 (see below). If you install the drive on the end of the SCSI bus, enable termination by installing a jumper on pins 15 and 16 of connector J2.

Image of Drive showing Jumpers

Terminator power

There are three possible terminator power configurations for the ST34501W drive. You will not normally need to change this option and can leave the drive configured as it was from the factory.

Parity check option

The default is parity check of the SCSI bus enabled. To disable this feature, install a jumper across pins 7-8 on J2.

Motor start option

Enable motor start. The drive waits for the Start Unit command from the host before starting the motor. Jumper across pins 11-12 on J2. Disable motor start (default) The drive starts according to the delay motor start option setting as described below.

Delay motor start option (Valid only if the Enable Motor Start jumper is not connected)

Enable motor start delay. Motor start delay is equal to the SCSI ID X 12 seconds. Install a jumper across pins 13-14 on J2. Disable motor start (default). Remove jumper from pins 13-14 on J2.

Write protect option

Write Protect = On (disables writing)   
        Jumper across pins 9-10 on J2.
Write Protect = Off (default) no jumper.